Wood Stove Installation and Repair in Spring Hill, FL

A freestanding stove set on the right hearth pad and connected to a chimney that is listed for solid fuel, from the stove collar to the cap.

  • Available for same-day service
  • Fully licensed and insured
  • Family owned and run
  • Locally owned and operated

Request a Free Inspection

Quicker by phone? Call (352) 663-0381

Same-day service available, call now

(352) 663-0381 Get a Free Inspection

10% Off Work Booked in the 72 Hours After Your Inspection

Book your wood stove installation within 72 hours of the free inspection and take 10% off.

What You Can Count On

Wood stove installation in Spring Hill puts a freestanding stove on a protected floor and connects it to a chimney rated for solid fuel. The crew keeps every clearance printed on the stove's label and in the chimney maker's instructions. The chimney then rises through the ceiling and roof, or leaves through an outside wall.

  • Family owned and run

    The same family crew plans the route and sets the chimney.

  • Upfront, honest pricing

    Chimney parts, pipe, pad and labor are itemized before work starts.

  • Workmanship warranty

    Our installation work is covered by our workmanship warranty.

Through the Roof or Out Through a Wall

Every wood burning stove installation in Spring Hill starts with one question: where does the chimney leave the house? By the Census Bureau's 2020 to 2024 estimates, close to nine in ten housing units in Spring Hill are single-family detached houses. Where your home is one of them, there are two honest routes. The chimney can rise straight up from the stove through the ceiling, the attic and the roof, or the pipe can turn, pass through an outside wall and climb the side of the house to above the eaves.

The stove maker's own advice favors the first. Drolet's wood stove manual says the chimney should be installed up through the heated space of the house, not out and up an outside wall, and should leave the roof at or near its highest point. A chimney inside the warm house keeps some draft even when no fire is burning. The same manual lists the signs of a poor route: cold air falling down the chimney when the stove is out, slow kindling, and smoke rolling out when the door is opened to load wood.

The wall route still has its place, for example where the stove has to sit against an outside wall or the roof is hard to reach. We explain what each route means for draft, for the roof and for the look of the room, and we price both when both are possible.

Getting a Listed Chimney Past the Roof Trusses

A wood stove does not vent into ordinary metal pipe. Under the Florida Building Code, Residential, section R1005.3, a factory-built chimney serving a solid-fuel appliance in a home must meet the Type HT requirements of UL 103, and R1005.1 says it is installed and finished exactly as its maker instructs. Drolet adds that only parts made for that brand and model of chimney may be used, never parts borrowed from another brand.

Where the attic is framed with roof trusses, the chimney has to pass between them. Section R802.10.4 says truss members are not cut, notched, drilled or altered in any way without the approval of a registered design professional. So on a wood stove chimney pipe installation we choose the stove position that lets the chimney rise between two trusses. If a small shift is needed, R1005.7 allows offsets of no more than 30 degrees from vertical and no more than four elbows. Where the chimney crosses attic insulation, R1005.8 calls for a steel insulation shield of at least No. 26 gage.

  • Ceiling support and trim collar at the room ceiling
  • Steel insulation shield where the chimney crosses attic insulation
  • Roof support, roof seal and storm collar from the chimney maker's kit
  • Rain cap made for that chimney brand

Where the Chimney Comes Out on the Roof

Height matters for draft and for safety. Drolet's manual asks for the chimney top to be at least 3 feet above the highest point where it touches the roof and at least 2 feet higher than any roof line or obstacle within 10 feet. A stove placed near the low edge of a long roof slope may need more chimney above the roof than one placed near the ridge, which is another reason the stove position and the chimney route are planned together.

The Escape 1200, one Drolet model, also lists a minimum total chimney height of 12 feet, measured from the stove. On a single-story house with a low ceiling, that number can decide whether a stove fits the room at all.

The Hearth Pad Under a Wood Stove

A wood stove hearth pad protects the floor from embers that fall out while you load wood. The Florida Building Code, section M1410.2, puts a room heater on a noncombustible floor or on noncombustible material that extends at least 18 inches beyond the stove on all sides, unless the stove is listed and the protector is listed and labeled to UL 1618, the standard for wall protectors, floor protectors and hearth extensions. In that case the stove's own manual sets the size.

Drolet's Escape 1200 manual is a good example of how specific that gets. It asks for a continuous noncombustible surface such as sheet steel, cement board, brick, or ceramic tile set with grout over a continuous noncombustible sheet, 16 inches in front of the door opening in the United States, and protection under any sideways run of pipe that reaches 2 inches past each side of it. On a concrete floor no pad is needed for that model. We read your stove's table, not a general rule, before we lay a single tile.

Connector Pipe From the Stove to the Chimney

In a wood stove pipe installation, the connector, or stovepipe, joins the stove collar to the chimney. Drolet calls it the weak link of a wood heating system, because a badly assembled connector has caused house fires. Its rules for single-wall pipe are plain: black painted pipe of at least 24 gauge, never galvanized; at least three screws at every joint; the male ends pointing down toward the stove; an upward slope toward the chimney; at most two 90-degree elbows and 10 feet of sideways run; and 18 inches from anything that can burn, or 9 inches with a proper shield.

The same manual says the pipe never passes through a combustible floor, ceiling, attic, closet or concealed space. Where the route goes through a wall or ceiling, the listed chimney takes over from the connector. Double-wall connector pipe follows its own maker's instructions, which allow closer clearances.

Using an Existing Masonry Chimney Instead

Some houses already have a brick chimney. A stove set in front of that fireplace can connect to it if the flue is lined and sized for the stove. Drolet's manual asks for a clay liner or a listed stainless liner, and says a square or rectangular flue larger than a round 6-inch flue should be relined with a listed 6-inch stainless liner. We handle that wood stove liner installation as part of the stove job. Where the pipe passes through a combustible wall to reach the chimney, an insulated listed thimble is required.

A stove that slides inside the firebox is a different job, covered by our fireplace insert installation page.

Before the First Fire

A new wood stove sold today must meet the EPA's 2020 emission limits and carry the permanent label that says so. The EPA notes the rules apply to new stoves only, not to stoves already in homes, so an older stove you are reinstalling may have no such label. Its maker's plate and manual still decide the clearances.

Drolet's wood stove manual requires a carbon monoxide detector and a smoke detector in the room where the stove is installed, and Drolet's installation manuals tell owners to contact local building or fire officials about restrictions and inspections. We check both before the first fire, light a small one with you, and leave the manuals and our written record of the work. A wrong clearance or a loose pipe joint can start a fire inside a wall or let carbon monoxide into the room, which is why this is not a weekend project.

We are a local, family-owned Spring Hill business and Proudly American, and the experienced crew that measures your room is the one that sets the chimney. Your stove plan starts with a free inspection and a written estimate.

Problems We Find and Fix

Smoke rolls out when the door opens
Often a cold chimney on an outside wall, or a long sideways pipe run. We look at the route before blaming the stove.
No hearth pad, or cracked tile
Embers can reach the wood floor. We size a pad from the stove's manual and the listed protector's label.
Mixed chimney brands
Factory-built chimneys are tested as one system. We replace parts that do not belong to it.

Repair Options

Which route fits depends on where the stove can sit and what is above it.

Stove can sit under open space between two trusses

Chimney straight up through the ceiling, attic and roof

Height above the roof and the attic insulation shield.

Stove must sit against an outside wall

Listed wall pass-through and chimney up the outside

Draft at start-up and height above the eaves.

House already has a sound brick chimney

Connect to the lined flue, or reline it to size

Liner size and the thimble through the wall.

Parts and Materials

Factory-built chimney
Listed to the Type HT requirements of UL 103, one brand from support to rain cap.
Connector pipe
Black single-wall pipe of 24 gauge or heavier, or listed double-wall pipe.
Floor protector
Noncombustible pad, or one listed to UL 1618, sized from the stove's table.
Attic insulation shield
Steel shield where the chimney passes through insulation.
Roof seal and storm collar
From the chimney maker's kit, sealed where the pipe leaves the roof.

Request Your Free Spring Hill Inspection

Leave your details and we will call back to pick a time that suits you.

(352) 663-0381
  • Free inspection and a written estimate
  • Same-day service available
  • Family owned and run in Spring Hill

Tell us what the chimney or fireplace is doing and we will phone to arrange the free inspection.

What Affects the Price

Route
Straight up through the roof or out through a wall.
Chimney length
Ceiling height, roof pitch and the height needed above the roof.
Hearth pad
Its size and material, set by the stove's manual.
Existing chimney
A brick flue that needs a new liner adds a separate step.

Signs It Is Time

A freestanding wood stove is only as safe as the floor under it and the chimney above it. Our family-run Spring Hill crew plans both before anything is bought or cut: where the chimney leaves the house, how it clears the attic framing, and what hearth pad the stove's manual calls for. You get that plan in writing after a free inspection.

  • You are adding a wood stove to a room that has no fireplace
  • An old stove is coming out and a newer one is going in
  • The existing stovepipe runs out a wall and the stove smokes at start-up
  • A stove sits on a rug, bare wood or loose tiles with no proper pad
  • You are not sure the chimney pipe was made for wood

Questions and Answers

Should a wood stove chimney go through the roof or through the wall?
Through the roof, when the house allows it. Drolet's manual says a chimney rising through the warm part of the house keeps better draft than one that exits a wall and climbs outside. A wall route still works when the stove must sit on an outside wall, but expect a slower start and plan the chimney height above the eaves.
What chimney pipe does a wood stove need?
A wood stove needs a factory-built chimney that meets the Type HT requirements of UL 103. Florida Building Code section R1005.3 holds a factory-built chimney serving a solid fuel appliance in a home to that standard. Inside the room, black single-wall or listed double-wall connector pipe joins the stove to it, and plain vent pipe made for gas appliances is not a substitute.
How do you install wood stove pipe?
Wood stove pipe goes together from the stove collar upward, with the first section held by three sheet metal screws. The male ends point down toward the stove, every joint gets at least three screws, and sideways runs slope upward toward the chimney. Drolet's manual also keeps single-wall pipe 18 inches from anything that can burn unless a shield is installed.
How is wood stove pipe installed through a roof?
The listed chimney, not the stovepipe, goes through the ceiling and roof. It passes between the roof trusses without cutting them, gets a steel insulation shield in the attic, and is sealed at the roof with the chimney maker's own parts. Drolet's manual then asks for at least 3 feet above the roof and 2 feet above anything within 10 feet.

Proudly American

Run by a Spring Hill family: experienced hands, a written estimate before work starts and a workmanship warranty on our repairs.

Call Now (352) 663-0381